BOD Analyzer Apparatus - เครื่องมือสำหรับการวิเคราะห์ค่า BOD

 

 

  BOD Incubator

No

 ขนาดภายใน

( ก x ลึก x สูง )

Accuracy

 Calibration 

 Timer 

Fan

 จำนวนชั้น 

Picture 

Brand

model

1

Aprox 140 L 

375 x 355 x 1130 มม.

 Range : 0 °c to 30 °c

 Resolutin = 0.1 °c 

 Stability = ± 0.2 °c

 Accuracy = ± 1°c

1 or 2 Point

No

 Yes , x1 

  5 ชั้น       (สแตนเลส)

 MLAB (Thailand)

 BIC 140

 

  BOD Meter  / DO Meter

 No 

ค่าที่วัดได้

Range

 Resolution 

Accuracy

 Calibration 

Loggger

Picture 

Brand

model

   

1

  DO

(dissoult oxygen)

 0.00-50.00 mg/L (ppm)

0.01 mg/L (ppm) ±1.5% rd.+1dg.

Auto 1 or 2 Poit @ 100% and 0%

 400 sample 

   

 HANNA (Italy)

 HI 98186

 

 0.0-600.0%  Saturation

0.1% Sat. ±1.5% rd.+1dg.

  Barometric Pressure

 450 to 850 mmHg

1 mmHg ±3 mmHg (with in 15% of cal. point) 1 Point

  Temperature

 -20 °c to 120.0 °c

0.1 °c ±0.2 °c 1 or  2 Point

Measurement mode : 1. direct DO ,2. BOD ,3. OUR (oxygen uptake rate) and 4. SOUR ( Specific oxygen uptake rate)

Temperature compensation : auto from 0 to 50 °c

Barometric Compensation : auto from 450 to 850 mmHg

Salinity Compensation : auto from 0 to  70 g/L

Electrode : HI764073 , Polarographic DO probe with Internal temperature sensor.

Log on demand : up to 400 samples

PC Connect : micro USB port. (ต้องซื้อ Software และสายต่อ)

Power : Battery 1.5V AA x4 ,

Battery life time : 200 hrs. without backlight (50 hrs. with backlight )

Auto off : 5 ,10 ,30 or 60 or disabled

Environment  : 0 to 50°c , 100%RH (IP67)

        

2

 DO

(dissoult oxygen)

 0.00-90.00 mg/L  (ppm)

 0.01 mg/L (ppm)

 ±1.5% rd.+1dg.

Auto or User standart  /  1 or 2 Point cal.

Up to 100 Lots.

Auto log. (10,000 samples/Lot)

Manual log.(5,000    samples/lot)

 

 HANNA (Italy)

 HI 4421

    

 0.0-600.0%  Saturation

 0.1% Sat.

 ±1.5% rd.+1dg.

 Barometric Pressure

 450 to 850 mmHg

(560 to 1133 mBar)

 1 mm Hg

 ±3 mm Hg + 1 least significant digit

1 Point

 Temperature

 -20.0 to 120.0°C

 0.1 °c

 N/A

N/A

Measurement mode : 1. direct DO ,2. BOD ,3. OUR (oxygen uptake rate) and 4. SOUR ( Specific oxygen uptake rate)

 

Temperature compensation : auto from 0 to 50 °c

 

Barometric Compensation : auto from 450 to 850 mmHg

 

Salinity Compensation : auto from 0 to  70 g/L

 

Electrode : HI764073 , Polarographic DO probe with Internal temperature sensor.

 

 

   อุปกรณ์ที่เกี่ยวข้อง
                 
                 
                 
  -    -    -    -
 
                 

 